Counter Flow and Cross Flow Cooling Tower (WYG-50T)
Square Molded Design · Compact Footprint · 50 m³/h Flow

The Challenge: Fitting Square Cooling into a Round World
Not every installation site is suited for round towers. Sometimes square is better. Square towers fit better in corners. Square towers use space more efficiently in some layouts. The Counter Flow and Cross Flow Cooling Tower (WYG-50T) is our square molded model. It delivers 50 m³/h of cooling water flow under standard conditions. It has a compact footprint of 1800+300 × 1400 × 1830 mm. It is designed for installations where round towers do not fit.
Real-World Case: HVAC Replacement in Zhejiang Office Building
A commercial office building in Zhejiang needed to replace an aging HVAC cooling tower. The available space was a rooftop area with a rectangular layout. A round tower would not fit without modifying the rooftop structure. The WYG-50T was installed in December 2024. The square shape fit perfectly in the corner of the rooftop. The building manager reported that the installation was straightforward and required no structural modifications.
"We needed a tower that would fit our rooftop layout. The square shape was perfect. Installation was quick, and the tower performs exactly as expected."
- Mr. Wang, Building Manager

Core Performance Specifications
|
Parameter |
Value |
|
Flow Rate (WB=27℃, 37℃-32℃) |
50 m³/h |
|
Flow Rate (WB=28℃, 37℃-32℃) |
40 m³/h |
|
Dimensions (L × W × H) |
1800+300 × 1400 × 1830 mm |
|
Power |
1.1 kW-6 |
|
Fan Diameter |
920 mm |
|
Air Volume |
21,000 m³/h |
|
Net Weight / Operating Weight |
460 kg / 1150 kg |
Why Is the Square Design Advantageous?
Space Efficiency
The square shape fits more efficiently in rectangular or square footprints. You can place it in a corner or against a wall without wasting space. The dimensions are 1800+300 × 1400 × 1830 mm - compact enough for rooftop installations with limited space.
Molded Construction
The shell is square molded FRP. The molding process creates a one-piece shell with consistent thickness and strength. No seams. No joints. No leak paths. The square design is structurally efficient for the intended size range.
Easy Access
Square towers often provide easier access to internal components because access panels can be placed on flat surfaces. The WYG-50T is designed with maintenance access in mind.
Why This Matters for Your Operation
If your installation site has a rectangular or square layout, a round tower wastes space. The WYG-50T uses space efficiently. It fits where round towers cannot. It gives you the same cooling capacity without requiring structural modifications.


Complete Technical Specification Table
|
Parameter |
Value |
|
Cooling Tower Type |
Counter Flow Square Molded |
|
Model |
WYG-50T |
|
Flow Rate (WB=27℃, 37℃-32℃) |
50 m³/h |
|
Flow Rate (WB=28℃, 37℃-32℃) |
40 m³/h |
|
L × W × H (mm) |
1800+300 Fan Hood × 1400 × 1830 |
|
Power |
1.1 kW-6 |
|
Fan Diameter |
920 mm |
|
Number of Blades |
4 |
|
Air Volume |
21,000 m³/h |
|
Inlet Pipe DN |
80 |
|
Outlet Pipe DN |
100 |
|
Drain Pipe DN |
32 |
|
Make-up Pipe DN |
20 |
|
Net Weight |
460 kg |
|
Operating Weight |
1150 kg |
Hot Tags: counter flow and cross flow cooling tower, China counter flow and cross flow cooling tower manufacturers, suppliers, factory, Cross Flow Type Cooling Tower, Galvanized Steel Cooling Tower, High temperature Cooling Tower, Medium temperature Square Cooling Tower, Spray Type Cooling Tower, square cooling tower