Counter Flow and Cross Flow Cooling Tower
video
Counter Flow and Cross Flow Cooling Tower

Counter Flow and Cross Flow Cooling Tower

Not every installation site is suited for round towers. Sometimes square is better. Square towers fit better in corners. Square towers use space more efficiently in some layouts. The Counter Flow and Cross Flow Cooling Tower (WYG-50T) is our square molded model.

Counter Flow and Cross Flow Cooling Tower (WYG-50T)

Square Molded Design · Compact Footprint · 50 m³/h Flow

product-800-800

The Challenge: Fitting Square Cooling into a Round World

Not every installation site is suited for round towers. Sometimes square is better. Square towers fit better in corners. Square towers use space more efficiently in some layouts. The Counter Flow and Cross Flow Cooling Tower (WYG-50T) is our square molded model. It delivers 50 m³/h of cooling water flow under standard conditions. It has a compact footprint of 1800+300 × 1400 × 1830 mm. It is designed for installations where round towers do not fit.

Real-World Case: HVAC Replacement in Zhejiang Office Building

A commercial office building in Zhejiang needed to replace an aging HVAC cooling tower. The available space was a rooftop area with a rectangular layout. A round tower would not fit without modifying the rooftop structure. The WYG-50T was installed in December 2024. The square shape fit perfectly in the corner of the rooftop. The building manager reported that the installation was straightforward and required no structural modifications.

"We needed a tower that would fit our rooftop layout. The square shape was perfect. Installation was quick, and the tower performs exactly as expected."
- Mr. Wang, Building Manager

product-800-800

 

Core Performance Specifications

 

Parameter

Value

Flow Rate (WB=27℃, 37℃-32℃)

50 m³/h

Flow Rate (WB=28℃, 37℃-32℃)

40 m³/h

Dimensions (L × W × H)

1800+300 × 1400 × 1830 mm

Power

1.1 kW-6

Fan Diameter

920 mm

Air Volume

21,000 m³/h

Net Weight / Operating Weight

460 kg / 1150 kg

 

Why Is the Square Design Advantageous?

 

Space Efficiency

The square shape fits more efficiently in rectangular or square footprints. You can place it in a corner or against a wall without wasting space. The dimensions are 1800+300 × 1400 × 1830 mm - compact enough for rooftop installations with limited space.

 

Molded Construction

The shell is square molded FRP. The molding process creates a one-piece shell with consistent thickness and strength. No seams. No joints. No leak paths. The square design is structurally efficient for the intended size range.

 

Easy Access

Square towers often provide easier access to internal components because access panels can be placed on flat surfaces. The WYG-50T is designed with maintenance access in mind.

Why This Matters for Your Operation

If your installation site has a rectangular or square layout, a round tower wastes space. The WYG-50T uses space efficiently. It fits where round towers cannot. It gives you the same cooling capacity without requiring structural modifications.

product-800-800
product-800-800 product-800-800

 

Complete Technical Specification Table

 

Parameter

Value

Cooling Tower Type

Counter Flow Square Molded

Model

WYG-50T

Flow Rate (WB=27℃, 37℃-32℃)

50 m³/h

Flow Rate (WB=28℃, 37℃-32℃)

40 m³/h

L × W × H (mm)

1800+300 Fan Hood × 1400 × 1830

Power

1.1 kW-6

Fan Diameter

920 mm

Number of Blades

4

Air Volume

21,000 m³/h

Inlet Pipe DN

80

Outlet Pipe DN

100

Drain Pipe DN

32

Make-up Pipe DN

20

Net Weight

460 kg

Operating Weight

1150 kg

 

Hot Tags: counter flow and cross flow cooling tower, China counter flow and cross flow cooling tower manufacturers, suppliers, factory, Cross Flow Type Cooling Tower, Galvanized Steel Cooling Tower, High temperature Cooling Tower, Medium temperature Square Cooling Tower, Spray Type Cooling Tower, square cooling tower