Low Noise Cooling Tower (WYG-30T)
61 dB(A) · Vibration Damping · Ideal for Noise-Sensitive Sites

The Challenge: Noise Complaints Shut Down Operations
Cooling towers are noisy. Fans generate noise. Water falling generates noise. Motors generate noise. In many locations, noise is regulated. Exceed the limit, and you face fines. Exceed the limit, and you face shutdown orders. The Low Noise Cooling Tower (WYG-30T) is designed for noise-sensitive sites. It operates at only 61 dB(A). It uses vibration damping. It is quiet enough for hospitals, schools, and residential areas.
Real-World Case: Hospital Cooling Plant in Hangzhou
A hospital in Hangzhou installed a WYG-30T in December 2024. The tower is located on the roof above patient rooms. The noise limit for the area is 65 dB(A) during the day and 55 dB(A) at night. The tower operates at 61 dB(A) - quiet enough for daytime operation. At night, the tower is operated at reduced speed to meet the 55 dB(A) limit. The hospital facility manager reported no noise complaints from patients or staff.
"We were worried about noise affecting patients. This tower is so quiet we barely notice it. No complaints. No issues."
- Ms. Zhou, Hospital Facility Manager

Core Performance Specifications
|
Parameter |
Value |
|
Cooling Water Flow Rate |
23.4 m³/h |
|
Inlet / Outlet Water Temperature |
37℃ / 32℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
117,000 kcal/h |
|
Noise Level |
61 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
16 kPa |
|
Net Weight / Operating Weight |
165 kg / 380 kg |
Why Is the WYG-30T So Quiet?
Optimized Fan Design
The fan is 630 mm in diameter with 4 nylon blades. The blade shape is aerodynamically optimized for low noise. The fan operates at low speed. Low speed means low noise. The nylon blades are lightweight and balanced. Balanced blades mean less vibration. Less vibration means less noise.
Vibration Damping
The tower structure is designed to dampen vibration. The motor is mounted on vibration isolators. The fan is balanced. The shell is rigid. Vibration is not transmitted to the building structure. The result is quiet operation.
Direct Drive Motor
The motor is 0.55 kW with direct drive. Direct drive eliminates the noise from belts and pulleys. Belts create noise as they flex. Pulleys create noise as they rotate. Direct drive is simpler and quieter.
Low Waterfall Noise
The water distribution system is designed to minimize waterfall noise. Water falls smoothly through the fill. The fill material breaks the water flow into small droplets. Small droplets create less noise than large water streams.
Why This Matters for Your Operation
Noise complaints shut down operations. They cost money. They damage reputations. The WYG-30T operates at 61 dB(A) - quiet enough for most noise-sensitive locations. It keeps your operation running without complaints.


Complete Technical Specification Table
|
Parameter |
Value |
|
Cooling Tower Type |
Counter Flow Round Water Tower |
|
Model |
WYG-30T |
|
Cooling Water Flow Rate |
23.4 m³/h |
|
Inlet / Outlet Water Temperature |
37℃ / 32℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
117,000 kcal/h |
|
Noise Level |
61 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Water Quality Requirement |
pH 6 – 8 |
|
Air-to-Water Ratio |
0.62 kg/kg |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
16 kPa |
|
Net Weight / Operating Weight |
165 kg / 380 kg |
|
Fan Type |
Axial Flow |
|
Air Volume |
10,725 m³/h |
|
Fan Diameter |
630 mm |
|
Number of Blades |
4 per set |
|
Drive Method |
Direct Drive |
|
Motor Power |
0.55 kW |
|
Motor Start Method |
Direct Start |
|
Water Basin Diameter (D) |
1390 mm |
|
Tower Height (H) |
2280 mm |
|
Inlet / Outlet Pipe Size (DN) |
60 mm / 60 mm |
|
Overflow / Drain Pipe Diameter (DN) |
25 mm / 25 mm |
|
Automatic / Manual Make-up Size (DN) |
15 mm / None |
|
Fan Material |
Nylon |
|
Shell Material |
Molded FRP |
|
Center Pipe Material |
PVC |
|
Rotating Head Material |
Nylon |
|
Water Distribution Pipe Material |
PVC |
|
Fill Material |
PVC |
|
Float Valve Material |
Nylon Float |
|
Rope Joint Material |
Nylon |
|
Air Intake System Material |
PVC |
Hot Tags: low noise cooling tower, China low noise cooling tower manufacturers, suppliers, factory, Cross Flow Type Cooling Tower, Galvanized Steel Cooling Tower, Low Noise Cooling Tower, Ultra Silent Cooling Tower, Vibration Damping Square Cooling Tower, Wet Cross Flow Cooling Tower