Low Noise Cooling Tower
video
Low Noise Cooling Tower

Low Noise Cooling Tower

Cooling towers are noisy. Fans generate noise. Water falling generates noise. Motors generate noise. In many locations, noise is regulated. Exceed the limit, and you face fines. Exceed the limit, and you face shutdown orders. The Low Noise Cooling Tower (WYG-30T) is designed for noise-sensitive sites.

Low Noise Cooling Tower (WYG-30T)

61 dB(A) · Vibration Damping · Ideal for Noise-Sensitive Sites

product-800-800

The Challenge: Noise Complaints Shut Down Operations

Cooling towers are noisy. Fans generate noise. Water falling generates noise. Motors generate noise. In many locations, noise is regulated. Exceed the limit, and you face fines. Exceed the limit, and you face shutdown orders. The Low Noise Cooling Tower (WYG-30T) is designed for noise-sensitive sites. It operates at only 61 dB(A). It uses vibration damping. It is quiet enough for hospitals, schools, and residential areas.

Real-World Case: Hospital Cooling Plant in Hangzhou

A hospital in Hangzhou installed a WYG-30T in December 2024. The tower is located on the roof above patient rooms. The noise limit for the area is 65 dB(A) during the day and 55 dB(A) at night. The tower operates at 61 dB(A) - quiet enough for daytime operation. At night, the tower is operated at reduced speed to meet the 55 dB(A) limit. The hospital facility manager reported no noise complaints from patients or staff.

"We were worried about noise affecting patients. This tower is so quiet we barely notice it. No complaints. No issues."
- Ms. Zhou, Hospital Facility Manager

product-800-800

 

Core Performance Specifications

 

Parameter

Value

Cooling Water Flow Rate

23.4 m³/h

Inlet / Outlet Water Temperature

37℃ / 32℃

Ambient Dry Bulb / Wet Bulb Temperature

31.5℃ / 27℃

Cooling Capacity

117,000 kcal/h

Noise Level

61 dB (A)

Power Supply

380V / 3P / 50Hz

Drift Loss

≤ 0.02%

Evaporation Loss

≤ 0.83%

Inlet Water Pressure

16 kPa

Net Weight / Operating Weight

165 kg / 380 kg

 

Why Is the WYG-30T So Quiet?

Optimized Fan Design

The fan is 630 mm in diameter with 4 nylon blades. The blade shape is aerodynamically optimized for low noise. The fan operates at low speed. Low speed means low noise. The nylon blades are lightweight and balanced. Balanced blades mean less vibration. Less vibration means less noise.

Vibration Damping

The tower structure is designed to dampen vibration. The motor is mounted on vibration isolators. The fan is balanced. The shell is rigid. Vibration is not transmitted to the building structure. The result is quiet operation.

Direct Drive Motor

The motor is 0.55 kW with direct drive. Direct drive eliminates the noise from belts and pulleys. Belts create noise as they flex. Pulleys create noise as they rotate. Direct drive is simpler and quieter.

Low Waterfall Noise

The water distribution system is designed to minimize waterfall noise. Water falls smoothly through the fill. The fill material breaks the water flow into small droplets. Small droplets create less noise than large water streams.

 

Why This Matters for Your Operation

Noise complaints shut down operations. They cost money. They damage reputations. The WYG-30T operates at 61 dB(A) - quiet enough for most noise-sensitive locations. It keeps your operation running without complaints.

product-800-800
product-800-800 product-800-800

 

Complete Technical Specification Table

 

Parameter

Value

Cooling Tower Type

Counter Flow Round Water Tower

Model

WYG-30T

Cooling Water Flow Rate

23.4 m³/h

Inlet / Outlet Water Temperature

37℃ / 32℃

Ambient Dry Bulb / Wet Bulb Temperature

31.5℃ / 27℃

Cooling Capacity

117,000 kcal/h

Noise Level

61 dB (A)

Power Supply

380V / 3P / 50Hz

Water Quality Requirement

pH 6 – 8

Air-to-Water Ratio

0.62 kg/kg

Drift Loss

≤ 0.02%

Evaporation Loss

≤ 0.83%

Inlet Water Pressure

16 kPa

Net Weight / Operating Weight

165 kg / 380 kg

Fan Type

Axial Flow

Air Volume

10,725 m³/h

Fan Diameter

630 mm

Number of Blades

4 per set

Drive Method

Direct Drive

Motor Power

0.55 kW

Motor Start Method

Direct Start

Water Basin Diameter (D)

1390 mm

Tower Height (H)

2280 mm

Inlet / Outlet Pipe Size (DN)

60 mm / 60 mm

Overflow / Drain Pipe Diameter (DN)

25 mm / 25 mm

Automatic / Manual Make-up Size (DN)

15 mm / None

Fan Material

Nylon

Shell Material

Molded FRP

Center Pipe Material

PVC

Rotating Head Material

Nylon

Water Distribution Pipe Material

PVC

Fill Material

PVC

Float Valve Material

Nylon Float

Rope Joint Material

Nylon

Air Intake System Material

PVC

 

Hot Tags: low noise cooling tower, China low noise cooling tower manufacturers, suppliers, factory, Cross Flow Type Cooling Tower, Galvanized Steel Cooling Tower, Low Noise Cooling Tower, Ultra Silent Cooling Tower, Vibration Damping Square Cooling Tower, Wet Cross Flow Cooling Tower