Main components and optional accessories of counter-flow closed cooling tower

Jun 10, 2026 Leave a message

Heat Exchange Coil: Employs a counter-current heat exchange design, where air and water exchange heat on the inner and outer sides of the coil. Materials used for the coil include titanium, copper, stainless steel, carbon steel, and aluminum. Titanium tubes are resistant to strong acid corrosion. Copper tube heat exchangers offer excellent heat dissipation and are widely used. Carbon steel tube heat exchangers can be hot-dip galvanized, but their internal corrosion protection is limited. Aluminum tubes have good thermal conductivity.

 

Fan: Utilizes a fully enclosed electric motor. The airfoil-shaped, wide-bladed aluminum alloy fan operates with low noise. The L10 bearing of the heavy-duty fan has a service life of 75,000 hours. A high-strength belt design is employed. Corrosion-resistant aluminum fan blades and motor pulleys are used internally.

 

Air Inlet: A multi-channel air inlet design reduces dust entry into the water pan, minimizing dust accumulation and microbial growth.

 

Shell: The closed-circuit cooling tower's shell can be made of galvanized steel sheet with a corrosion-resistant surface treatment. For higher corrosion resistance, stainless steel plates can be used.

 

The main body of the equipment is equipped with adjustable spray components and detachable components. The adjustable spray components include a drive component and an adjustment component. The drive component drives the adjustment component to rotate, spraying cooling water into the main body of the equipment. The detachable component is used to block external impurities and needs to be replaced regularly .

 

Water pan electric heater assembly: In environments below freezing temperature, measures must be taken to prevent the water in the water pan from freezing. The water pan electric heater can be used to maintain the water temperature. The electric heater assembly includes an electric heater, a temperature relay, and a low water level cut-off switch.

 

Dual-speed motor: A dual-speed motor can provide capacity control. When the load decreases or the wet-bulb temperature changes, the fan does not need to run at full load, which helps save energy. Running the fan at low speed also reduces noise.

 

Variable frequency motor: A variable frequency motor is suitable for applications requiring variable frequency drive to achieve capacity control.

 

Electronic water level controller: Cooling towers can be equipped with electronic water level controllers to replace mechanical float water supply devices, which are characterized by more precise water level control. Maintenance and Operation Platform: The cooling tower can be equipped with an operation platform for maintenance of the drive components. This platform is equipped with a straight ladder and is typically installed on the side of the access door in the unit's casing section.

 

Water Pan Silencer: A water pan silencer is installed in the unit's water pan to reduce water drip noise.

 

Vibration Shut-off Switch: The cooling tower can be equipped with a mechanical or electronic vibration trip switch to prevent malfunctions caused by excessive vibration of the drive system.