Anti Scaling Round Cooling Tower
video
Anti Scaling Round Cooling Tower

Anti Scaling Round Cooling Tower

If your facility uses hard water, you know the problem. Scale builds up on fill material. Scale builds up on the water distribution system. Scale reduces cooling efficiency. Scale clogs nozzles. Scale forces you to shut down for cleaning. Scale costs you money. The Anti Scaling Round Cooling Tower (WYG-100H) is designed for hard water areas.

Anti Scaling Round Cooling Tower (WYG-100H)

Designed for Hard Water · Reduced Scale Build-Up · Lower Maintenance Frequency

product-800-800

The Challenge: Scale Is a Maintenance Nightmare

If your facility uses hard water, you know the problem. Scale builds up on fill material. Scale builds up on the water distribution system. Scale reduces cooling efficiency. Scale clogs nozzles. Scale forces you to shut down for cleaning. Scale costs you money. The Anti Scaling Round Cooling Tower (WYG-100H) is designed for hard water areas. It uses hot-dip galvanized steel for the water distribution system. It uses heat-resistant nylon for components exposed to high temperatures. It is built to resist scale formation and reduce maintenance frequency.

Real-World Case: Plastics Plant in Hebei

A plastics plant in Hebei Province uses well water with high mineral content. Their previous tower required cleaning every 45 days. Scale build-up reduced cooling efficiency by 15%. The WYG-100H was installed in January 2025. The plant manager reports that after 9 months of operation, scale build-up is minimal. The first cleaning was performed at 6 months - four times longer than the previous tower. Cooling efficiency has remained stable.

"We were cleaning our old tower every month. This tower ran for six months before we needed to clean it. That's a huge difference in labor cost and downtime."
- Mr. Zhang, Plant Manager

(Maintenance logs are available upon request.)

product-800-800

 

Core Performance Specifications

 

Parameter

Value

Cooling Water Flow Rate

90 m³/h

Inlet / Outlet Water Temperature

60℃ / 40℃

Ambient Dry Bulb / Wet Bulb Temperature

31.5℃ / 27℃

Cooling Capacity

390,000 kcal/h

Noise Level

64 dB (A)

Power Supply

380V / 3P / 50Hz

Drift Loss

≤ 0.02%

Evaporation Loss

≤ 0.83%

Inlet Water Pressure

21 kPa

Net Weight / Operating Weight

700 kg / 1600 kg

 

Why Does the WYG-100H Resist Scale?

Hot-Dip Galvanized Steel Water Distribution

The water distribution pipe and center pipe are hot-dip galvanized steel. The hot-dip galvanizing process creates a thick, uniform zinc coating. This coating prevents scale from adhering to the pipe surface. Scale that does not adhere is washed away by the water flow. The smooth galvanized surface also resists corrosion. Standard steel pipes have rough surfaces that promote scale formation. Galvanized steel is smoother. Scale has less surface area to grip.

Heat-Resistant Nylon Components

The float ball and rope joint are made of heat-resistant nylon. These materials do not degrade in 60℃ water. They do not corrode. They maintain their mechanical properties over time. This reduces the need for replacement parts.

PPC Fill Material

The fill material is heat-resistant PPC. PPC is resistant to scale formation. Scale does not easily adhere to PPC surfaces. The fill material maintains its surface area for heat exchange. Cooling efficiency does not degrade as quickly.

Aluminum Alloy Fan

The fan is aluminum alloy. It is lightweight and corrosion-resistant. It does not rust. It does not require painting. It maintains aerodynamic efficiency over time.

 

Why This Matters for Your Operation

Scale costs you money in three ways. It reduces cooling efficiency. It forces maintenance shutdowns. It causes premature component failure. The WYG-100H is designed to reduce all three costs. Less scale means better efficiency. Less scale means fewer shutdowns. Less scale means longer component life. This tower is built to work in hard water conditions.

product-800-800
product-800-800 product-800-800

 

About Us - A Cooling Equipment Manufacturer You Can Trust

 

Key Metric

Data

Total Customers Served

Over 5,600

2025 Annual Sales

Exceeded RMB 29 million

Payment Collection Rate

98.2%

Since

2010

 

Complete Technical Specification Table

 

Parameter

Value

Cooling Tower Type

Counter Flow Round Water Tower

Model

WYG-100H

Cooling Water Flow Rate

90 m³/h

Inlet / Outlet Water Temperature

60℃ / 40℃

Ambient Dry Bulb / Wet Bulb Temperature

31.5℃ / 27℃

Cooling Capacity

390,000 kcal/h

Noise Level

64 dB (A)

Power Supply

380V / 3P / 50Hz

Water Quality Requirement

pH 6 – 8

Air-to-Water Ratio

0.62 kg/kg

Drift Loss

≤ 0.02%

Evaporation Loss

≤ 0.83%

Inlet Water Pressure

21 kPa

Net Weight / Operating Weight

700 kg / 1600 kg

Fan Type

Axial Flow

Air Volume

42,900 m³/h

Fan Diameter

1450 mm

Number of Blades

4 per set

Drive Method

Direct Drive

Motor Power

2.2 kW-8

Motor Start Method

Direct Start

Water Basin Diameter (D)

2900 mm

Tower Height (H)

3260 mm

Inlet / Outlet Pipe Size (DN)

125 mm / 125 mm

Overflow / Drain Pipe Diameter (DN)

50 mm / 50 mm

Automatic / Manual Make-up Size (DN)

20 mm / None

Fan Material

Aluminum Alloy

Shell Material

Molded FRP

Center Pipe Material

Hot-Dip Galvanized Steel

Rotating Head Material

Aluminum Alloy

Water Distribution Pipe Material

Hot-Dip Galvanized Steel

Fill Material

PPC Heat-Resistant

Float Ball Material

Heat-Resistant Nylon

Rope Joint Material

Heat-Resistant Nylon

Air Intake System Material

PVC

 

Hot Tags: anti scaling round cooling tower, China anti scaling round cooling tower manufacturers, suppliers, factory, Anti Scaling Round Cooling Tower, Counter Current Cooling Tower, High Temperature Round Cooling Tower, Large Capacity Round Cooling Tower, Round Type Cooling Tower, Small Round Cooling Tower