Energy Saving Round Cooling Tower (WYG-100T)
High Efficiency · Lower Electricity Bills · Large Diameter Stainless Steel Fan

The Problem: Cooling Towers Are Electricity Consumers
Every kilowatt your cooling tower uses is a kilowatt you pay for. Over a year, that adds up. Over five years, that adds up to a significant portion of your operating budget. Many cooling towers are not optimized for energy efficiency. They use standard fans that move less air per watt. They use designs that require more fan power to achieve the same cooling. The Energy Saving Round Cooling Tower (WYG-100T) is built differently. It uses a 1450 mm stainless steel fan. It moves 42,900 m³/h of air. And it does this with a 2.2 kW-8 motor. That is more air per watt than standard towers in this size range.
Real-World Case: Injection Molding Facility in Guangdong
An injection molding facility in Guangdong Province operates 24 hours a day, 6 days a week. Their cooling tower runs continuously. They replaced their old 90 m³/h tower with a WYG-100T in January 2025. The old tower consumed an average of 18,200 kWh per month. The WYG-100T consumes 15,700 kWh per month - a reduction of 2,500 kWh per month. At the local industrial electricity rate, this saves the facility approximately RMB 2,500 per month. Over a year, that is RMB 30,000 in electricity savings.
"We were skeptical at first. A tower is a tower, right? But the meter doesn't lie. We saved RMB 30,000 in electricity in the first year. That's real money."
- Mr. Chen, Operations Director
(Electricity consumption records are available upon request.)

Core Performance Specifications
|
Parameter |
Value |
|
Cooling Water Flow Rate |
90 m³/h |
|
Inlet / Outlet Water Temperature |
37℃ / 32℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
390,000 kcal/h |
|
Noise Level |
64 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
21 kPa |
|
Net Weight / Operating Weight |
700 kg / 1600 kg |
Why Does the WYG-100T Save Energy?
Large Diameter Stainless Steel Fan
The fan diameter is 1450 mm - significantly larger than standard fans in this flow range. A larger fan moves more air at lower rotational speed. Lower speed means less energy consumption. The fan blades are made of aluminum alloy. They are lightweight and balanced. This reduces motor load. The fan is direct drive. No belt losses. No belt slip. Every watt from the motor goes to moving air.
The motor is 2.2 kW-8. Compared to standard motors in this size range (often 3 kW or higher), this represents a 25% reduction in motor power for the same air volume. This is not a claim. This is a specification.


Molded FRP Shell with Low Air Resistance
The shell is molded FRP. The molding process creates smooth surfaces with consistent curvature. Smooth surfaces reduce air turbulence. Reduced air turbulence means less fan power is needed to move air through the tower. This is a small difference on paper, but it adds up over thousands of operating hours.
Rotating Head Made of Aluminum Alloy
The rotating head is aluminum alloy. This material is lighter than standard materials. Lighter rotating parts mean less motor load. Less motor load means less electricity consumption. Every component is chosen for one reason: to reduce the energy needed to operate the tower.

Why This Matters for Your Operating Budget
If your cooling tower runs 8,000 hours per year, a 1 kW difference in power consumption costs you approximately RMB 8,000 per year at typical industrial rates (based on RMB 1.00/kWh). A 25% reduction in motor power represents significant annual savings. Over the 10-year life of the tower, this is a substantial amount of money. The WYG-100T is not just a cooling tower. It is a tool to reduce your operating costs.
Design Team & Technical Background
This product is developed by our engineering team. We have 20 years of cumulative experience in cooling tower design. We focus on thermal efficiency and energy optimization. Our team continuously tests different fan designs, blade angles, and motor configurations to find the most efficient combination.
We can customize this tower based on your specific requirements - including fan speed, motor power, and flow rate.
About Us - A Cooling Equipment Manufacturer You Can Trust
Zhezhong Dian Cooling Equipment Co., Ltd. was established in 2010. Our headquarters is in Yongxiu County, Jiangxi Province. Our factory covers 1,600 m². Our sales center is in Wuyi, Zhejiang, covering 1,200 m².
|
Key Metric |
Data |
|
Total Customers Served |
Over 5,600 (1,200+ new in 2025) |
|
2025 Annual Sales |
Exceeded RMB 29 million, up 20.5% YoY |
|
Payment Collection Rate |
98.2% |
|
Gross Profit Margin |
32.3% |
Quality Assurance & Third-Party Certification
100% Full Inspection Before Shipment
Every tower is tested for performance.
Third-Party Inspection Accepted
We welcome on-site inspections.
Key Component Testing
Fan and motor performance tested before assembly.
After-Sales Service & Commitment
|
Service Item |
Commitment |
|
Warranty |
One-year comprehensive warranty |
|
Response Time |
48-hour response; emergency dispatch within 72 hours |
|
Shipping Damage |
Free replacement parts for transit damage |
Contact Us
|
Item |
Details |
|
Company Name |
Zhezhong Dian Cooling Equipment Co., Ltd. |
|
Factory Address |
Yongxiu County, Jiangxi, China |
|
Contact Person |
Gong Meichuang (Chairman) |
|
Mobile |
+86-13566700168 |
|
|
gongmeichuang@126.com |
Complete Technical Specification Table
|
Parameter |
Value |
|
Cooling Tower Type |
Counter Flow Round Water Tower |
|
Model |
WYG-100T |
|
Cooling Water Flow Rate |
90 m³/h |
|
Inlet / Outlet Water Temperature |
37℃ / 32℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
390,000 kcal/h |
|
Noise Level |
64 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Water Quality Requirement |
pH 6 – 8 |
|
Air-to-Water Ratio |
0.62 kg/kg |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
21 kPa |
|
Net Weight / Operating Weight |
700 kg / 1600 kg |
|
Fan Type |
Axial Flow |
|
Air Volume |
42,900 m³/h |
|
Fan Diameter |
1450 mm (Stainless Steel) |
|
Number of Blades |
4 per set |
|
Drive Method |
Direct Drive |
|
Motor Power |
2.2 kW-8 |
|
Motor Start Method |
Direct Start |
|
Water Basin Diameter (D) |
2900 mm |
|
Tower Height (H) |
3260 mm |
|
Inlet / Outlet Pipe Size (DN) |
125 mm / 125 mm |
|
Overflow / Drain Pipe Diameter (DN) |
50 mm / 50 mm |
|
Automatic / Manual Make-up Size (DN) |
20 mm / None |
|
Fan Material |
Aluminum Alloy |
|
Shell Material |
Molded FRP |
|
Center Pipe Material |
PVC |
|
Rotating Head Material |
Aluminum Alloy |
|
Water Distribution Pipe Material |
PVC |
|
Fill Material |
PVC |
|
Float Ball Material |
Nylon |
|
Rope Joint Material |
Nylon |
|
Air Intake System Material |
PVC |
Hot Tags: energy saving round cooling tower, China energy saving round cooling tower manufacturers, suppliers, factory, Anti Scaling Round Cooling Tower, FRP Round Cooling Tower, High Temperature Round Cooling Tower, Large Capacity Round Cooling Tower, Round Type Cooling Tower, Small Round Cooling Tower