Industrial Round Counter Flow Cooling Tower (WYG-80H)
Heavy Duty · High Temperature · Continuous Operation

The Challenge: Industrial Cooling That Never Stops
Industrial facilities do not shut down for maintenance on a schedule that is convenient. They run continuously. They need equipment that can run with them. The Industrial Round Counter Flow Cooling Tower (WYG-80H) is built for continuous industrial operation. It handles 68.4 m³/h of water at 60℃ inlet temperature. It uses a stainless steel fan and galvanized steel water distribution pipe. It is built to last in demanding industrial environments.
Real-World Case: Steel Finishing Plant in Tangshan
A steel finishing plant in Tangshan replaced three failing cooling towers with one WYG-80H unit in March 2025. The old towers used standard steel components that corroded rapidly in the plant's water chemistry environment. The WYG-80H uses stainless steel for the fan and galvanized steel for the water distribution system. The plant maintenance manager reports that after 10 months of operation, there is no visible corrosion on the key components. The tower has run continuously without any unplanned maintenance.
"Our old towers were a maintenance nightmare. The galvanized steel in this tower is holding up perfectly. No rust. No corrosion. It just runs."
- Mr. Huang, Maintenance Manager
(Maintenance records are available upon request.)

Core Performance Specifications
|
Parameter |
Value |
|
Cooling Water Flow Rate |
68.4 m³/h |
|
Inlet / Outlet Water Temperature |
60℃ / 40℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
320,000 kcal/h |
|
Noise Level |
62.5 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
19 kPa |
|
Net Weight / Operating Weight |
400 kg / 1000 kg |
Why Is the WYG-80H Built for Industry?
Stainless Steel Fan
The fan is made of stainless steel. Standard fans corrode in industrial environments. Stainless steel does not. It resists rust, chemical attack, and weather exposure. The fan diameter is 1180 mm with 4 blades. It moves 35,320 m³/h of air. The fan maintains its efficiency over time because it does not corrode.
Galvanized Steel Water Distribution System
The water distribution pipe and center pipe are both galvanized steel. Galvanized steel resists corrosion better than standard steel. It handles 60℃ water without degradation. It resists chemical treatment additives. The galvanized layer protects the steel underneath. Even if the surface is scratched, the galvanized layer provides cathodic protection to prevent rust.
Molded FRP Shell
The shell is molded FRP. It is corrosion-resistant, lightweight, and strong. It does not rust. It does not require painting. It maintains its structural integrity over decades of service.
Direct Drive Motor
The motor is 1.5 kW-8 with direct drive. No belts to replace. No belt tension to adjust. Direct drive is more reliable than belt drive in industrial environments. Fewer parts to fail. Less maintenance required.
Why This Matters for Your Operation
Industrial environments are hard on equipment. Corrosion is a constant threat. Standard materials fail. The WYG-80H uses materials that resist corrosion. Stainless steel fan. Galvanized steel piping. FRP shell. These materials last longer. They require less maintenance. They keep your production line running.


About Us - A Cooling Equipment Manufacturer You Can Trust
|
Key Metric |
Data |
|
Total Customers Served |
Over 5,600 |
|
2025 Annual Sales |
Exceeded RMB 29 million, up 20.5% YoY |
|
Active Customer Rate |
65% |
|
Since |
2010 |
Complete Technical Specification Table
|
Parameter |
Value |
|
Cooling Tower Type |
Counter Flow Round Water Tower |
|
Model |
WYG-80H |
|
Cooling Water Flow Rate |
68.4 m³/h |
|
Inlet / Outlet Water Temperature |
60℃ / 40℃ |
|
Ambient Dry Bulb / Wet Bulb Temperature |
31.5℃ / 27℃ |
|
Cooling Capacity |
320,000 kcal/h |
|
Noise Level |
62.5 dB (A) |
|
Power Supply |
380V / 3P / 50Hz |
|
Water Quality Requirement |
pH 6 – 8 |
|
Air-to-Water Ratio |
0.62 kg/kg |
|
Drift Loss |
≤ 0.02% |
|
Evaporation Loss |
≤ 0.83% |
|
Inlet Water Pressure |
19 kPa |
|
Net Weight / Operating Weight |
400 kg / 1000 kg |
|
Fan Type |
Axial Flow |
|
Air Volume |
35,320 m³/h |
|
Fan Diameter |
1180 mm |
|
Number of Blades |
4 per set |
|
Drive Method |
Direct Drive |
|
Motor Power |
1.5 kW-8 |
|
Motor Start Method |
Direct Start |
|
Water Basin Diameter (D) |
2100 mm |
|
Tower Height (H) |
2850 mm |
|
Inlet / Outlet Pipe Size (DN) |
100 mm / 100 mm |
|
Overflow / Drain Pipe Diameter (DN) |
25 mm / 25 mm |
|
Automatic / Manual Make-up Size (DN) |
20 mm / None |
|
Fan Material |
Stainless Steel |
|
Shell Material |
Molded FRP |
|
Center Pipe Material |
Galvanized Steel |
|
Rotating Head Material |
Nylon |
|
Water Distribution Pipe Material |
Galvanized Steel |
|
Fill Material |
PP |
|
Float Valve Material |
Nylon |
|
Rope Joint Material |
Nylon |
|
Air Intake System Material |
PVC |
Hot Tags: industrial round counter flow cooling tower, China industrial round counter flow cooling tower manufacturers, suppliers, factory, Counter Current Cooling Tower, Counter Flow Type Cooling Tower, Energy Saving Round Cooling Tower, FRP Round Cooling Tower, Industrial Round Counter Flow Cooling Tower, Small Round Cooling Tower